Restore the water supply.
Inspect the wells, test water quality and sustainable yield, then specify suitable replacement pumps, controls and power. Pump selection depends on the operating water level, required flow and delivery pressure.
Virgin Mary Farm · A practical first step
Our latest update from Sudan reports that the seven wells remain intact, but their pumps are broken and need replacing. Our proposed next step is to restore pumping and build a reservoir, creating a water supply for growing and practical training.
Our proposed direction
Our proposed routine is to pump during daylight, when solar power is available, and fill a new reservoir for the planned vegetable greenhouses. Battery storage would support agreed electrical needs outside daylight hours; its capacity and connected equipment remain to be designed.
See how the water could travel
A connected pathway: wells → reservoir → filter and controls → greenhouse drip irrigation.
An example to discuss with the technical designer
There is no single standard commercial greenhouse size. For this comparison only, imagine ten greenhouses measuring 10 × 50 metres each: 5,000 m² of total floor area. These dimensions have not been selected for the farm.
Choose an example usable storage volume:
100,000 litresExample usable water storage · not the final reservoir recommendation
| Assumed use per m² of floor area | Water per day, 10 greenhouses | Stored supply, without refilling |
|---|---|---|
| 2 litres/day | 10,000 litres | 10 days |
| 5 litres/day | 25,000 litres | 4 days |
| 8 litres/day | 40,000 litres | 2.5 days |
These arbitrary comparison rates show the arithmetic; they are not measured needs for Sudan or a particular crop. Figures exclude storage and distribution losses, filter washing, cooling, any salinity management and other farm uses. Actual demand depends on crop mix, planted area, season and growing method. A larger reservoir cannot make up for a continuing shortage of water supply.
Assuming one barrel holds approximately 200 litres, filling it in ten minutes gives 1.2 m³/hour per well. If all seven sustained that rate together, the combined historical rate would be 8.4 m³/hour. Twelve hours would give 100.8 m³; this is not a current test or a solar output forecast.
For example only, six equivalent hours at that full combined flow would give 50.4 m³ (50,400 litres). Six hours is an arithmetic input, not a prediction of local sunshine or pump performance. Solar output varies through the day. Confirm the barrel capacity and gallon standard, test all wells, and model the solar system before setting a daily supply figure.
That rectangular water volume equals 100 m³, or 100,000 litres. This is a volume illustration only, not an excavation or construction specification. A real reservoir needs allowance for unusable storage, freeboard, any sloping sides and lining, plus a suitable ground assessment, overflow, drainage and safe access. Its overall dimensions would therefore differ.
Next design step: confirm greenhouse sizes and a seasonal crop plan; measure sustainable well yield and pumping water levels; then calculate peak daily demand, refill performance and the agreed reserve. Specify reservoir geometry, pumps, solar panels, batteries and irrigation pressure as one coordinated system.
Inspect the wells, test water quality and sustainable yield, then specify suitable replacement pumps, controls and power. Pump selection depends on the operating water level, required flow and delivery pressure.
Develop a lined reservoir or suitable tank storage, with protection against contamination and safe access. Its size, lining and any cover will follow the water assessment and crop needs.
Use a main pipe with controlled branches to the planned greenhouses. Filtered drip lines would supply water close to plant roots, with each irrigation zone controlled separately.
Pumping and irrigation can run at different times
We plan to use solar-powered replacement pumps during daylight to fill the reservoir, replacing the earlier proposed 6 pm to 6 am pumping routine. Stored water would then be available for irrigation when crops need it, subject to the designed pressure supply.
Battery storage is also proposed. Its size will follow the agreed loads and operating hours, including any irrigation booster or controls needed outside daylight. It is not yet specified to run all seven well pumps overnight. Gravity supply or an irrigation booster will depend on site levels and pressure.
Why explore solar power?
The Global Solar Atlas reports a countrywide range of approximately 5.5–6.7 kWh/m² per day for long-term average global horizontal solar irradiation. This is sunlight energy reaching a horizontal surface, not electricity produced by a panel or guaranteed pump operating hours.
The farm’s solar design will use its exact location and monthly conditions, with allowances for heat, dust, shading and system losses. Sustainable well yield and the required pumping head must also be measured before choosing pumps, panel capacity or batteries.
Source: Global Solar Atlas · Sudan, based on long-term solar-resource modelling through 2018. National figures provide context, not a farm-specific energy forecast.
A system designed for this farm
We aim to connect water supply, suitable energy and practical training in one coordinated system. The design would follow the farm’s land, crops, water quality and operating needs, and could expand as production develops.
Test the well water, including salinity, and assess the soil and crops before choosing irrigation equipment. Filtration would protect drip lines; any additional water treatment would depend on the test results.
Assess renewable power alongside available reliable supplies. Compare pumping schedules, energy use, operating costs and maintenance so the chosen system suits local conditions.
Include training in pump operation, filter cleaning, irrigation controls and routine checks. Agree servicing, spare parts and clear maintenance responsibilities before handover.
Well condition and operating water levels; sustainable pumping rates and interaction between wells; water quality; greenhouse dimensions and crops; daily irrigation demand; storage capacity; site elevations; pipe routes; power availability; security, maintenance and a costed first-stage plan. The reported well depth of approximately 500 feet does not by itself determine pump size or water output.
The earlier barrel-filling account is historical information, not a current pump test or a confirmed supply for ten greenhouses.
FAO: drip irrigation components, filtration and pressure control. FAO: solar pumping and water storage. FAO: assessing irrigation water quality. These explain general principles; the farm’s design needs a qualified site assessment.
Help develop the first working system
Can you help assess the wells, design solar pumping and storage, supply suitable equipment or train local operators? Contact Iman to discuss the proposed first stage.
Email i.tadros@risemeup.org or use the main contact section. Equipment specifications and reservoir capacity remain subject to technical assessment.